Designed for high-pressure and high-temperature applications for a wide range of fluids excepts slurries and viscous fluids.
These valves are generally used in the wide open or closed position, are not recommended for throttling service because throttling causes disc shattering and vibration which is likely to erode seating surface cause leakage.
When in open position the gate rises allowing the fluid to flow with a minimum pressure drop.
Can be installed a vertical or horizontal position without affecting the direction of the line.
Specifications
Manufacturing Standard
API 600 / API 6D / BS 1414
End to end dimensions
ANSI B 16.10 / DIN 3230
Inspection
& Test Std.
API 598 / BS 6755
Ends
Flanged to ANSI B 16.5 BS 10 BUTTWELD to ANSI B 16.25